By William McDonald


Electrical components carry current that needs to be controlled regularly. For this reason, there ought to be components connected to devices transmitting electricity. Markedly, a high voltage contactor is used to regulate current by allowing devices to be switched on and off. Various devices that must have fuses are explained in the paragraphs below.

Three elements work together to allow full functioning of fuses. These components are a coil, pole, and auxiliary. To start with, valves are switched on and off by coils. They are spiraled to reduce the distance traveled by signals, hence allow faster action. Poles transmit power signals to fuses. Finally, auxiliaries are used for paneling as well as indicating circuit application.

Connectors are commonly applied in the paneling of lighting. Large buildings such as commercial as well as offices require that lighting is controlled from a central point. Great current switches are best suited for this due to their ability to transmit strong electrons. Since coils may consume more power in such applications, latching valves are used instead. These have two coils. One is powered temporarily hence suited for closing circuits. The opening coil is suited for establishing connections.

Great current connectors are also used in vacuum contacts. Vacuum connectors are switches which make use of valves compressed in void bottles. These allow suppression of arcs which in turn pushes valves to a smaller size. For this reason, those fuses can be used in dirty processes such as mining. Additionally, vacuum valves are preferred in applications which utilize relatively strong electric energy. This is because they displace oil-filled circuit breakers easily.

Mercury transmitters also utilize connectors. Electric signals in such devices are moved through liquefied mercury. Since mercury reacts easily with air, it is contained in an airtight container. Containers are further lined with insulation materials to prevent heating. For this reason, cycling surfaces which easily corrode with time may utilize such valves. However, usage of mercury relays is reducing since mercury is not environmental friendly. Solid connectors are used in place of these.

Another usage is in mercury-wetted relays. These are transmitters whereby valves are first moistened with mercury before use. However, they may not be categorized as contacts due to the amount of voltage used. Normally, they operate on currents below 15 amperes, unlike other circuits.

Another usage is in camshafts also known as transformers. Camshafts are special transmitters that utilize numerous circuits aligned sequentially. Electric magnets would be best, but they cannot be used individually. Switch efficiency in transformers is more improved since electric current may be powered by electric motors or gas cylinders. Initially, camshafts were widely used to speed up electric locomotives.

Connectors may also be used in magnetic starters. These devices are important in starting electric locomotives. Valves are used to control the amount of energy transferred through coils. At any given time, contacts may not overload. For this reason, they are best for the provision of automatic circuit breaking.




About the Author:



These icons link to social bookmarking sites where readers can share and discover new web pages.
  • Digg
  • Sphinn
  • del.icio.us
  • Facebook
  • Mixx
  • Google
  • Furl
  • Reddit
  • Spurl
  • StumbleUpon
  • Technorati